Application: | Nc Machine Tool |
---|---|
Speed: | Constant Speed |
Number of Stator: | Two-Phase |
Samples: |
Nema23
|
---|
Customization: |
---|
Shipping Cost:
Estimated freight per unit. |
about shipping cost and estimated delivery time. |
---|
Payment Method: | |
---|---|
Initial Payment Full Payment |
Currency: | US$ |
---|
Return&refunds: | You can apply for a refund up to 30 days after receipt of the products. |
---|
Suppliers with verified business licenses
Phases | 2 | ||
Step Angle | 1.8 | ° | |
Volts | 5.7 | V DC | |
AMPS | 1 | A/phase | |
D.C Resistance | 5.7 | Ω±10% at 25ºC | |
Coil Inductance | 29.4 | Mh±20% at 1K Hz, 1 V [RMS] | |
b Holding Torque | 141.6 | oz.in (1.0 N.m) | |
at I=1 A/phase 2Ex | |||
Note1. | Pull out Torque | 110 | oz.in (0.78 N.m). at 200 pulse/s |
© | Inertial Load 14.2 oz.in² (2.6×10−4Kg.m² ) | ||
© | Inertial of Rubber coupling is included | ||
Note1. | Max. Starting Rate | 640 | pulse / s Min. at No Load |
Note1. | Max. Slewing Rate | 800 | pulse / s Min. at No Load |
Note2. | Positional Accuracy | ±0.054 | °(0.108° Spread Max.) 2Ex. |
Coil Temperature Rise | 80 | K Max. | |
Rotor Inertia | 1.15 | oz.in² (0.21×10−4Kg.m² ) Nominal | |
Insulation Class | B | ||
© | Allowable Thrust Load | 15 | N |
© | Allowable Radial Load | 56 | N Load to Shaft End. |
Note1. Sanyo Standard 2 Phase excitation drive circuit was used E=24V [DC], I=1 A/phase.(AVERAGE VALUE) |
|||
Note2. Mount A motor on 6.3×6.3×2.4t(160×160×6t) Aluminum heat sink and energize a coil at 2 phase excitation, I=1 A/phase constant. |
|||
Note3. Center hole on the shaft end is not always made. |
|||
© | Note4. A color scheme of lead wire of motor's outlet is discretion. |
2. Wiring Connection | 3. Direction of Rotation | ||||||
When a motor is sequenced as shown in the table bellow, the shaft rotation must be clockwise when you see from suface ®side | |||||||
RED | BLUE | YELLOW | ORANGE | ||||
STEP | 1 | Θ | Θ | ⊕ | ⊕ | ||
2 | ⊕ | Θ | Θ | ⊕ | |||
3 | ⊕ | ⊕ | Θ | Θ | |||
4 | Θ | ⊕ | ⊕ | Θ |
Constant current circuit | ||
Surpply Vottage: | DC 24 V | |
Coil Current: | 1A/ Phase | |
Full step 2 Phase on | ||
JL=2.6×(1÷10000 )kg.m² | ||
fs: Maximum automatic start frequency at no-load |
5.External Dimension: